hyload-multi

Cold Applied

A cold applied, moisture cured, single component roofing membrane adhesive using polyether technology. Fast curing elastomeric membrane which cures into a seamless monolithic rubber-like system that is resistant to thermal shock.
Tech Data PDF
 

Product Highlights

  1. Solvent free
  2. Moisture cure
  3. High solids will not shrink
  4. No outgassing on damp surfaces
  5. Bonds to green concrete
  6. Safe for occupied buildings
  7. Can be used on EPS insulation or iso-board,
  8. Non flammable
  9. Ideal for Schools, Hospitals, or Food Processing facilities
  10. OSHA Compliant
  11. Very low odor
  12. May be used in confined spaces
  13. Conforms to OTC Rule for Sealants
  14. Conforms to USDA Requirements for Nonfood Contact
  15. Meets requirements of California Regs: CARB and SCAQMD
  16. This product does not contain cancer causing chemicals listed in California Proposition 65
  17. NAHB Model Green Home Building Guidelines: 5 Global Impact Points
  18. VOC Content: Less than 36 grams /liter ASTM D2369 EPA Method 24 (Tested at 240̊ F / 115ͦ C)

Applications and Packaging

Applications

  • Hyload Roofing membrane adhesion
  • Hyload Fleece back membrane adhesion
  • Roofing repair

Packaging

  • Black Colored
  • 5 Gallon Pails
  • 36 Pails per pallet
  • 50 Gallon drums by request

h150e2
H150E

Substrates and Performance Properties

  • The substrate should be smooth, level, clean, and dry.
  • Include but not limited to Wood, Masonry, Steel, Aluminum, Stone, Galvanized Metal, Asphalt BUR, Modified Bitumen, EPS Protection Board, Styrofoam Protection Board, and Concrete.
  • Hyload CPA can be installed directly over existing Hyload membranes without priming. Priming with Hyload HyPrime is recommended on all other substrates

Performance Properties

GradeLiquid Applied
Viscosity35,000 cp
+/- 15,ooo cp
Brookfield RVF TE
Spindle, 4 RPM
Specific Gravity11.2 +/- 0.2 lbsASTM D1475
Tack Free Time 60 +/- 40 minASTM C679
Low Temp. FlexPass 1/4 inch
Mandrel -10°F
ASTM D816
ShrinkageNo visible shrinkage

Limitations and Warranty

  • Hyproof CPA is not intended for use with a permanently exposed surface • In areas where prolonged chemical exposure is anticipated, contact Technical Services for recommendations.
  • Do not store in elevated temperatures.
  • Remove all coatings and sealants before application.
  • Do not apply at temperatures below 35°F (2°C).
  • DO NOT THIN WITH SOLVENTS, WATER, OR OTHER FOREIGN MATERIAL • DO NOT USE AN ASPHALT PRIMER

Warranty

Hyload makes available to its customers several high performance product warranties.  Contact Hyload’s Corporate Office directly for details. A standard warranty is 10 years.