HYKOTE 900 WP COMPLETE for Waterproofing
HyKote™ 900 WP Complete is a flexible, elastomeric, ready-to-use single component, fluid-applied,
solvent based 100% rubber waterproofing membrane for commercial building roofs that is applied in a two-coat application process. HyKote 900 WP Complete does not require insulation, drainage or protection panels.
HyKote™ 900 WP Complete is a flexible, elastomeric, ready-to-use single component, fluid-applied, solvent based 100% rubber waterproofing membrane for commercial building roofs that is applied in a two-coat application process. HyKote 900 WP Complete does not require insulation, drainage or protection panels. After allowing the membrane to properly cure (for 48 hours), the foundation can be backfilled. HyKote 900 WP Complete is available in gray or green in 5–gallon pails or 50–gallon (net by weight) drums. HyKote 900 WP Complete is manufactured in our ISO 9001:2008 Registered facility located in Seville, Ohio.
HyKote WP 900 Complete is compliant with ICC, as it has passed the AC 29 requirements per an accredited independent laboratory.
AC 29 Acceptance Criteria for Cold, Liquid-Applied, Below Grade,
Exterior Dampproofing and Waterproofing Materials (Approved June 2011)
Color1 | NA | Dark Gray or Green | —— |
Asphalt Content1 | NA | 0.0% | —— |
Thickness1 | ASTM D 3767 | 40 mils ( nominal ) | —— |
Tensile Strength, Membrane1 | ASTM D 412 | 491.5 psi | —— |
Elongation, Membrane1 | ASTM D 412 | 860.5 % | —— |
Resistance to deterioration in contacting soil | ASTM E 154 (3 tests below) |
||
Weight Loss ( % ) | ASTM E 96-00 | 6.6 | ≤ 10 |
Water Vapor Permeance ( Perm ) | 0.2 | ≤ 1 | |
Hydrostatic Pressure over cracks ( ft of water ) |
ASTM C 1306-95 | 69.3 | Report 50% of Lowest value |
Resistance to Water [ Pass/Fail ] | ASTM D 2939 | Pass | No blistering or re-emulsification |
Remain in Place During Application [ Pass/Fail ] |
ASTM C 836 | Pass | As recommended by Mfg ± 5 mils |
Adhesion-in-peel (after water immersion) ( lb/in ) | ASTM C 836 | 5.3 | ≥ 1 |
Low Temperature Crack Bridging[ Pass/Fail ] | ASTM C 1305 | Pass | No Cracking |
Extensibility after Heat Aging[ Pass/Fail ] | ASTM C 1522 / ASTM C 836 | Pass | No Cracking |
1 Property not part of AC 29 testing requirements