HYKOTE™ 900 WP COMPLETE for Waterproofing
HyKote™ 900 WP Complete is a flexible, elastomeric, ready-to-use single component, fluid-applied,
solvent based 100% rubber waterproofing membrane for commercial building roofs that is applied in a two-coat application process. HyKote™ 900 WP Complete does not require insulation, drainage or protection panels.
HyKote™ 900 WP Complete is a flexible, elastomeric, ready-to-use single component, fluid-applied, solvent based 100% rubber waterproofing membrane for commercial building roofs that is applied in a two-coat application process. HyKote™ 900 WP Complete does not require insulation, drainage or protection panels. After allowing the membrane to properly cure (for 48 hours), the foundation can be backfilled. HyKote™ 900 WP Complete is available in gray or green in 5–gallon pails or 50–gallon (net by weight) drums. HyKote™ 900 WP Complete is manufactured in our ISO 9001:2008 Registered facility located in Seville, Ohio.
HyKote™ WP 900 Complete is compliant with ICC, as it has passed the AC 29 requirements per an accredited independent laboratory.
AC 29 Acceptance Criteria for Cold, Liquid-Applied, Below Grade,
Exterior Dampproofing and Waterproofing Materials (Approved June 2011)
Color1 | NA | Dark Gray or Green | —— |
Asphalt Content1 | NA | 0.0% | —— |
Thickness1 | ASTM D 3767 | 40 mils ( nominal ) | —— |
Tensile Strength, Membrane1 | ASTM D 412 | 491.5 psi | —— |
Elongation, Membrane1 | ASTM D 412 | 860.5 % | —— |
Resistance to deterioration in contacting soil | ASTM E 154 (3 tests below) |
||
Weight Loss ( % ) | ASTM E 96-00 | 6.6 | ≤ 10 |
Water Vapor Permeance ( Perm ) | 0.2 | ≤ 1 | |
Hydrostatic Pressure over cracks ( ft of water ) |
ASTM C 1306-95 | 69.3 | Report 50% of Lowest value |
Resistance to Water [ Pass/Fail ] | ASTM D 2939 | Pass | No blistering or re-emulsification |
Remain in Place During Application [ Pass/Fail ] |
ASTM C 836 | Pass | As recommended by Mfg ± 5 mils |
Adhesion-in-peel (after water immersion) ( lb/in ) | ASTM C 836 | 5.3 | ≥ 1 |
Low Temperature Crack Bridging[ Pass/Fail ] | ASTM C 1305 | Pass | No Cracking |
Extensibility after Heat Aging[ Pass/Fail ] | ASTM C 1522 / ASTM C 836 | Pass | No Cracking |
1 Property not part of AC 29 testing requirements